Urban water reuse: microbial pathogens control by direct filtration and ultraviolet disinfection

Tipo de material: TextoTextoSeries ; Journal of Water and Health, 12(3), p.465-473, 2014Trabajos contenidos:
  • De Lima Isaac, R
  • Dos Santos, L.U
  • Tosetto, M.S
  • Franco, R.M.B
  • Guimarães, J.R
Tema(s): Recursos en línea: Resumen: Physicochemical treatment efficiency for unrestricted urban water reuse was evaluated at a conventional activated-sludge wastewater treatment plant (WWTP). Pilot plant set-up consisted of an alum coagulation step, granular media upflow flocculation and direct downflow dual-media filtration followed by ultraviolet disinfection (dose of 95 mJ cm-2). Optimum aluminum sulfate dosage of 10 mg L-1 and coagulation pH 7.0 were preset based on bench scale tests. Under WWTP stable operation, water quality met United States Environmental Protection Agency (USEPA)suggested guidelines for unrestricted urban reuse regarding turbidity (mean value 1.3 NTU)and suspended solids (mean value 2.1 mg L-1). When WWTP overall plant performance dropped from 90 to 80 percent (although BOD value stayed below 6 mg O2 L-1, suggesting unrestricted reuse), solids breakthrough in filtrate was observed. Microorganism removal rates were: total coliforms 60.0 percent, Escherichia coli 63.0 percent, Giardia spp. 81.0 percent, and helminth eggs 62.5 percent; thus organisms still remained in filtrate. Ultraviolet (UV)disinfection efficiency was 4.1- and 3.8-log for total coliforms and E. coli, respectively. Considering low UV efficiency obtained for helminths and the survival of protozoa and helminths in the environment, effluent quality presents risk to public health if destined for unrestricted urban reuse.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode
Documentos solicitados Documentos solicitados CICY Documento préstamo interbibliotecario Ref1 B-16282 (Browse shelf(Opens below)) Available

Physicochemical treatment efficiency for unrestricted urban water reuse was evaluated at a conventional activated-sludge wastewater treatment plant (WWTP). Pilot plant set-up consisted of an alum coagulation step, granular media upflow flocculation and direct downflow dual-media filtration followed by ultraviolet disinfection (dose of 95 mJ cm-2). Optimum aluminum sulfate dosage of 10 mg L-1 and coagulation pH 7.0 were preset based on bench scale tests. Under WWTP stable operation, water quality met United States Environmental Protection Agency (USEPA)suggested guidelines for unrestricted urban reuse regarding turbidity (mean value 1.3 NTU)and suspended solids (mean value 2.1 mg L-1). When WWTP overall plant performance dropped from 90 to 80 percent (although BOD value stayed below 6 mg O2 L-1, suggesting unrestricted reuse), solids breakthrough in filtrate was observed. Microorganism removal rates were: total coliforms 60.0 percent, Escherichia coli 63.0 percent, Giardia spp. 81.0 percent, and helminth eggs 62.5 percent; thus organisms still remained in filtrate. Ultraviolet (UV)disinfection efficiency was 4.1- and 3.8-log for total coliforms and E. coli, respectively. Considering low UV efficiency obtained for helminths and the survival of protozoa and helminths in the environment, effluent quality presents risk to public health if destined for unrestricted urban reuse.