MARC details
| 000 -LEADER |
| fixed length control field |
02579nam a2200277Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER |
| control field |
MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20250625124651.0 |
| 040 ## - CATALOGING SOURCE |
| Transcribing agency |
CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
B-6916 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT |
| Title |
Thermal performance of a discontinuous finned heatsink profile for PV passive cooling. |
| 490 0# - SERIES STATEMENT |
| Volume/sequential designation |
Applied Thermal Engineering, 184, p.116238, 2021 |
| 520 3# - SUMMARY, ETC. |
| Summary, etc. |
In this work, an improved CFD model based on previous results is used to evaluate the scaling effects on thermal and hydraulic performance of a passive heatsink design for PV panel cooling purposes. PV systems efficiency degrades when operating temperature increases, a common incidence in hot climates exposed to high solar irradiance. In order to reduce the operating temperature of PV modules and maintain their efficiency, a segmented fin heatsink is proposed, whose performance under varying wind attack conditions outperforms the conventional continuous fin profile heatsink design. Numerical simulations using computational fluid dynamics software are presented, assessing different levels of heatsink fin segmentation (fin width)and its effect on hydraulic performance, as well as temperature level and homogeneity of the PV module. Two prototypes were built for experimental evaluation: the model with better results in the numerical tests, and a conventional design homologue, both manufactured following a cost-effective ratio and using 22-gauge aluminum sheet. Numerical simulation showed a temperature reduction of up to 7 °C using the proposed heatsink, as well as a lower temperature gradient. Regarding hydraulic performance, the segmented fin profile reduces pressure losses up to 49 percent when compared to a conventional heatsink. Experimental results are in good agreement, as thermal images showed a mean temperature reduction of around 5 °C and similar homogeneity. The proposed heatsink design shows improved hydraulic characteristics, thus enhancing heat transfer using the same amount of material as a conventional design. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
PASSIVE COOLING |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
COMPUTATIONAL FLUID DYNAMICS |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
FINNED HEATSINK |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
HEAT TRANSFER ENHANCEMENT |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name entry element |
PV SYSTEM |
| 700 12 - ADDED ENTRY--PERSONAL NAME |
| Personal name |
Hernandez-Perez, J. G., |
| 700 12 - ADDED ENTRY--PERSONAL NAME |
| Personal name |
Carrillo, J. G., |
| 700 12 - ADDED ENTRY--PERSONAL NAME |
| Personal name |
Bassam, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME |
| Personal name |
Flota-Banuelos, M. |
| 700 12 - ADDED ENTRY--PERSONAL NAME |
| Personal name |
Patino-Lopez, L. D |
| 856 40 - ELECTRONIC LOCATION AND ACCESS |
| Uniform Resource Identifier |
<a href="https://drive.google.com/file/d/1P2wLjRf5Q0_uTTO9Z94-V1M-9x2-emU2/view?usp=drivesdk">https://drive.google.com/file/d/1P2wLjRf5Q0_uTTO9Z94-V1M-9x2-emU2/view?usp=drivesdk</a> |
| Public note |
Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Source of classification or shelving scheme |
Clasificación local |
| Koha item type |
Documentos solicitados |