Development of new generation coupling agents for wood-plastic composites (Record no. 41936)

MARC details
000 -LEADER
fixed length control field 01871nam a2200169Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250625124704.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-7612
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title Development of new generation coupling agents for wood-plastic composites
490 0# - SERIES STATEMENT
Volume/sequential designation Intertech Conference The Global Outlook for Natural and Wood Fiber Composites New Orleans, LA, 2003
520 3# - SUMMARY, ETC.
Summary, etc. Advanced high performance coupling agents were developed for wood-plastic composite (WPC)applications. These new products utilize a proprietary composition and grafting process that provides superior performance compared to typical maleic anhydride grafted coupling agents. In this paper a series of polyethylene based coupling agents were tested for performance in WPC. First, the effect of coupling agents on enhancing the mechanical properties and in reducing water sorption of WPC was investigated in injection molding as well as profile extrusion processes. Second, the mechanism of coupling and the relationship to enhancement in performance was studied using several analytical techniques: small strain oscillatory rheology; dynamic mechanical analysis (DMA); scanning electron microscopy (SEM); Fourier Transform Infrared Spectroscopy (FTIR); and thermo gravimetric analysis (TGA). The effect of lubricants on WPC performance was thoroughly evaluated. It was determined through molecular investigations that certain lubricants can have a detrimental effect on the performance of coupling agents. Recommendations on how to optimize WPC performance through the selection of proper formulation components are presented.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Botros, M.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1CSvFmYV_jDHVORYnWr-hXqrUoiJFqcsf/view?usp=drivesdk">https://drive.google.com/file/d/1CSvFmYV_jDHVORYnWr-hXqrUoiJFqcsf/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-7612 25.06.2025 25.06.2025 Documentos solicitados