Thermal degradation and fire resistance of unsaturated polyester, modified acrylic resins and their composites with natural fibres (Record no. 42013)

MARC details
000 -LEADER
fixed length control field 02006nam a2200265Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250625124706.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-7690
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title Thermal degradation and fire resistance of unsaturated polyester, modified acrylic resins and their composites with natural fibres
490 0# - SERIES STATEMENT
Volume/sequential designation Polymer Degradation and Stability, 91(2), p.255-261, 2006
520 3# - SUMMARY, ETC.
Summary, etc. The thermal degradation and fire resistance of different natural fibre composites were studied. Unsaturated polyester (UP)and modified acrylic resins (Modar)were used as matrix composites. The smoke emission of the materials was also analysed, as well as, the performance against the fire of the biocomposites and glass reinforced composites was compared. Thermal degradation indicated that the Modar matrix composites were more resistant to temperature than the composites with UP matrix. Flax fibre, due to their low lignin content, exhibit the best thermal resistance among the natural fibres studied. From the results obtained about the thermal and fire resistance of the composites it is possible to conclude that the flax fibre seems to be the most adequate to be used, due to the long time to ignition and the long period prior to reach the flashover. On the other hand, the jute fibre composites showed a short duration but a quick growing fire with the lowest smoke emission. The low smoke is an important advantage, which reduces one of the main hazards of fire.
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element UNSATURATED POLYESTER
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element NATURAL FIBRES
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element THERMAL DEGRADATION
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element FIRE RESISTANCE
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element SMOKE EMISSION
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Manfredi, L.B.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Rodríguez, E.S.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Wladyka-Przybylak, M.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Vázquez, A.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1jOHMLAXlFrrUNiiIAbfn7JHo8fMLB-8o/view?usp=drivesdk">https://drive.google.com/file/d/1jOHMLAXlFrrUNiiIAbfn7JHo8fMLB-8o/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-7690 25.06.2025 25.06.2025 Documentos solicitados