Effect of anode backing layer on the cell performance of a direct methanol fuel cell (Record no. 42273)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01913nam a2200253Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625124711.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-7961 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Effect of anode backing layer on the cell performance of a direct methanol fuel cell |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Electrochimica Acta, 51(25), p.5524-5531, 2006 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | We investigated experimentally the effect of the anode backing layers consisting of carbon papers with different thicknesses and different polytetrafluoroethylene (PTFE)contents on the cell performance of a direct methanol fuel cell (DMFC). The membrane electrode assemblies were prepared using the decal method such that the effect of different anode backing layers could be studied with the same anode catalyst layer, the same membrane and the same cathode. We found that a too thin anode backing layer resulted in lower cell voltages in the entire current density region, whereas a too thick backing layer led to a lower limiting current density. The reduced cell performance as a result of thinning the backing layer may be attributed mainly to the increased under-rib mass transport polarization as a result of weaker under-rib convection in a thinner backing layer. The experimental results also showed that the use of a PTFE-treated backing layer resulted in a lower limiting current density, attributing primarily to the increased mass transfer resistance as a result of the PTFE treatment. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | DIRECT METHANOL FUEL CELLS |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | MASS TRANSFER |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | DIFFUSION LAYER |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | WETTABILITY |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | NON-UNIFORMITY |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Xu, C. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Zhao, T.S. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ye, Q. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/19iF2sOJU4jTGLY4uySLCCqF_OOQ7eID0/view?usp=drivesdk">https://drive.google.com/file/d/19iF2sOJU4jTGLY4uySLCCqF_OOQ7eID0/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-7961 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
