Sulfonated PEEK-WC membranes for proton-exchange membrane fuel cell: Effect of the increasing level of sulfonation on electrochemical performances (Record no. 43105)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02398nam a2200277Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625124727.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-8804 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Sulfonated PEEK-WC membranes for proton-exchange membrane fuel cell: Effect of the increasing level of sulfonation on electrochemical performances |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Journal of Membrane Science, 281(1-2), p.377-385, 2006 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Sulfonation of PEEK-WC powder (a glassy poly-ether ether ketone)has been performed at 80 .C for 3 h using H2SO4 conc. (96 percent). The degree of sulfonation varied from 15 to 40 percent, depending on the reaction time. The sulfonated polymers (S-PEEK-WC)were used to prepare dense membranes for possible fuel cell application. In particular, two membranes were prepared by solvent evaporation technique, usingDMAas the solvent for the 2-and 3-h sulfonated polymers. The dense character of both membranes has been confirmed by SEM analysis. The chemical.physical characterization has showed an increasing water solubility of the sulfonated polymers with the increasing level of sulfonation: from 7 to 11percent of weight loss at 80 .C in pure water. Despite this, a water uptake increase up to 15percent has been found for the dense membranes at 80 .C. Furthermore, if compared with a commercial Nafion membrane, S-PEEK-WC membranes exhibit comparable electrochemical performances even if at higher temperature, especially the membrane prepared with the 3-h sulfonated polymer. A power density of 284 mW/cm2 was obtained for S-PEEK-WC membrane at 120 .C in H2/air fuel cell, slightly above the corresponding value found for Nafion. At the same temperature, a Tafel slope of 70mV was reached for the S-PEEK-WC membrane versus 100mV for the Nafion. Finally, the specific conductivity is about 1.7_~10.2 S/cm versus 1.4_~10.1 S/cm of the commercial Nafion membrane. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PEEK-WC |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | SULFONATION |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | FUEL CELL |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | HYDROGEN |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PROTON-EXCHANGE MEMBRANE |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Basile, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Paturzo, L. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Iulianelli, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Gatto, I. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Passalacqua, E. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1Wt3j27llZgb4eBZzvny8WIgKMk1Y3QvJ/view?usp=drivesdk">https://drive.google.com/file/d/1Wt3j27llZgb4eBZzvny8WIgKMk1Y3QvJ/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-8804 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
