Porous polyurethane vascular prostheses with variable compliances (Record no. 43413)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01438nam a2200181Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625124733.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-9156 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Porous polyurethane vascular prostheses with variable compliances |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Journal of Biomedical Materials Research, 26(11), p.1489-1502, 1992 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | The surgical reconstruction of diseased arteries with synthetic vessels has provided significantly satisfactory results for patients.'-4 However, surgical operations have been limited to the relatively large-diameter high-f low, lowresistance vessels (greater than 6 mm in inner diameter)including the aorta, iliac, and femoral vessels. Small-diameter vessels (less than 6 mm in inner diameter)are not in general clinical use due to their limited long-term biocompatibility and low patency rates in experimental testing. Anastomotic hyperplasia may require revision. Anastomotic hyperplasia occurs in synthetic artificial grafts but also in grafts from mammary veins and arteries as well as autogenous veins and arteries. This complication has been suggested to result partially from compliance mismatch. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Liu, S. Q. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Kodama, M. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1r2yFgFdJOejrfMv3bKDXOEFS4ELtt0rZ/view?usp=drivesdk">https://drive.google.com/file/d/1r2yFgFdJOejrfMv3bKDXOEFS4ELtt0rZ/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-9156 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
