Effect of ultrasound sonication in nanoclay clusters of nanoclay/epoxy composites (Record no. 44326)

MARC details
000 -LEADER
fixed length control field 02008nam a2200241Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250625140625.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-10085
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title Effect of ultrasound sonication in nanoclay clusters of nanoclay/epoxy composites
490 0# - SERIES STATEMENT
Volume/sequential designation Materials Letters, 59(11), p.1369-1372, 2005
520 3# - SUMMARY, ETC.
Summary, etc. Ultrasound sonication has been widely used in the exfoliation of nanoclay platelets. Nevertheless, the existence of absolutely exfoliated nanoclay composites is impossible in reality. Regions of intercalated nanoclay platelets can be easily formed and agglomerate as tiny clusters. Different sizes of clusters mixed by nanoclays and matrix would be easily formed, particularly in the extrusion of polymer-based components. The effects of ultrasound sonication in these intercalated nanoclay clusters will be detailedly discussed in this paper. The hardness of nanoclay/epoxy composites samples made under different ultrasound sonication time will be examined to compare their mechanical performances. X-ray diffraction (XRD)technique will also be employed to investigate the interplanar distance between the nanoclay platelets in different samples. Scanning electron microscopy (SEM)will also be used to investigate the clusters distribution inside the composites. The results show that there exists an optimum ultrasound sonication time where the mechanical properties of the composites are mostly enhanced. The cluster sizes of nanoclay change with different sonicating time, whereas the interplanar distance without being altered
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element NANOCOMPOSITES
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element HARDNESS
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element ULTRASOUND SONICATION
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Lam, C.K.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Lau, K.T.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Cheung, H.Y.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Ling, H.Y.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1f6JFXd2xsqR3STTZd20Xwq0lD8letW_r/view?usp=drivesdk">https://drive.google.com/file/d/1f6JFXd2xsqR3STTZd20Xwq0lD8letW_r/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-10085 25.06.2025 25.06.2025 Documentos solicitados