Design, fabrication and performance analysis of a 200W PEM fuel cell short stack (Record no. 44626)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02200nam a2200265Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625140630.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-10389 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Design, fabrication and performance analysis of a 200W PEM fuel cell short stack |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Journal of Power Sources, 171(1), p.179-185, 2007 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | A PEM fuel cell short stack of 200Wcapacity, with an active area of 100 cm2 has been designed and fabricated in-house. The status of unit cell performance was 0.55Wcm-2. Based on the unit cell technology, a short stack has been developed. The proper design of uniform flow distribution, cooling plate and compressed end plate were important to achieve the best performance of the short stack. The performance of four cells stack was analyzed in static and dynamic modes. In the static mode of polarization curve, the stack has peak power density of 0.55Wcm-2 (220 W)at 0.5V per cell, when the voltage was scanning from low to high voltage (1.5-3.5 V), and resulted in minimum water flooding inside the stack. In this study a series of dynamic loadings were tested to simulate the vehicle acceleration. The fuel cell performances respond to dynamic loading influenced by the hydrogen/air stoichiometric, back pressure, and dynamic-loading time. It was needed high hydrogen stoichiometric and back pressure to maintain high dynamic performance. In the long-time stable power testing, the stack was difficult to maintain at high performance, due to the water flooding at high output power. An adjusting cathode back-pressure method for purging water was proposed to prevent the water flooding at flow channels and maintain the stable output power at 170W (0.42Wcm-2). |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PEM FUEL CELL |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | STACK DESIGN |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | DYNAMIC PERFORMANCE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | HYSTERESIS EFFECT |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Weng, F.B. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Jou, B.S. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Su, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Chan, S.H. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Chi, P.H. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1VXXUNTxb19CvK3LCOim1OiDSL5G5hsuR/view?usp=drivesdk">https://drive.google.com/file/d/1VXXUNTxb19CvK3LCOim1OiDSL5G5hsuR/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-10389 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
