Investigating microbial fuel cell bioanode performance under different cathode conditions (Record no. 45673)

MARC details
000 -LEADER
fixed length control field 02069nam a2200205Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250625140651.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-11457
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title Investigating microbial fuel cell bioanode performance under different cathode conditions
490 0# - SERIES STATEMENT
Volume/sequential designation Biotechnology progress, 25(6), p.1630-1636, 2009
520 3# - SUMMARY, ETC.
Summary, etc. A compact, three-in-one, flow-through, porous, electrode design with minimal electrode spacing and minimal dead volume was implemented to develop a microbial fuel cell (MFC)with improved anode performance. A biofilm-dominated anode consortium enriched under a multimode, continuous-flow regime was used. The increase in the power density of the MFC was investigated by changing the cathode (type, as well as catholyte strength)to determine whether anode was limiting. The power density obtained with an air-breathing cathode was 56 W/m(3)of net anode volume (590 mW/m(2)) and 203 W/m(3)(2160 mW/m(2)) with a 50-mM ferricyanide-based cathode. Increasing the ferricyanide concentration and ionic strength further increased the power density, reaching 304 W/m(3)(3220 mW/m(2), with 200 mM ferricyanide and 200 mM buffer concentration). The increasing trend in the power density indicated that the anode was not limiting and that higher power densities could be obtained using cathodes capable of higher rates of oxidation. The internal solution resistance for the MFC was 5-6 Omega, which supported the improved performance of the anode design. A new parameter defined as the ratio of projected surface area to total anode volume is suggested as a design parameter to relate volumetric and area-based power densities and to enable comparison of various MFC configurations
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Borole, A.P,
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Hamilton, C.Y.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Aaron D.S.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Tsouris, C.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1ERSGGRFYxhKBq-zoZm8CfTpjg64MeFV8/view?usp=drivesdk">https://drive.google.com/file/d/1ERSGGRFYxhKBq-zoZm8CfTpjg64MeFV8/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-11457 25.06.2025 25.06.2025 Documentos solicitados