Analysis and Improvement of a Scaled-Up and Stacked Microbial Fuel Cell (Record no. 45853)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01771nam a2200217Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625140654.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-11637 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Analysis and Improvement of a Scaled-Up and Stacked Microbial Fuel Cell |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Environ. Sci. Technol., 43(23), p.9038-9042, 2009 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Scaling up microbial fuel cells (MFCs)is inevitable when power outputs have to be obtained that can power electrical devices other than small sensors. This research hasusedabipolar plate MFC stack of four cells with a total working volume of 20 L and a total membrane surface area of 2 m2. The cathode limited MFC performance due to oxygen reduction rate and cell reversal. Furthermore, residence time distribution curves showed that bending membranes resulted in flow paths through which the catholyte could flow from inlet to outlet, while leaving the reactants unconverted. The cathode was improved by decreasing the pH, purging pure oxygen, and increasing the flow rate, which resulted in a 13-fold power density increase to 144 W m-3 and a volumetric resistivity of only 1.2 mÙ m3 per cell. Both results are major achievementscomparedto results currently published for laboratory and scaled-up MFCs. When designing a scaled-up MFC, it is important to ensure optimal contactbetweenelectrodesandsubstrateandto minimize the distances between electrodes. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Dekker, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Heijne, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Saakes, M. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Hamelers, H.V.M. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Buisman, C.J.N. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1QnZRCLMcFml4vdwqLtrAxGQG10aIdhed/view?usp=drivesdk">https://drive.google.com/file/d/1QnZRCLMcFml4vdwqLtrAxGQG10aIdhed/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-11637 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
