Flow maldistribution in interdigitated channels used in PEM fuel cells (Record no. 45937)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01778nam a2200229Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625140656.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-11721 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Flow maldistribution in interdigitated channels used in PEM fuel cells |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Journal of Power Sources, 159(1), p.595-604, 2006 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | The interdigitated flow configuration is unique in the sense that the reactants are forced through the porous electrodes in this configuration, whereas this occurs by diffusion in the conventional types of flow fields. Previous studies have shown that this reduces the possibility of flooding of the cathode electrode resulting in improved efficiency of the fuel cell, however, at the cost of a higher-pressure drop. In the present study, computational fluid dynamics (CFD)-based simulations have been used to study the effect of important geometric parameters such as the channel, the header and the electrode dimensions. The results show that for low permeabilities the flow is uniform across the porous electrode; however, for permeabilities in the range of 10-11 to 10-10 m2, the flow may become non-uniform. Under these conditions, calculations in four-cell and eight-cell parallel interdigitated configuration show that significant flow maldistribution among the parallel channels is likely to occur. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PEM FUEL CELLS |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | FLOW MALDISTRIBUTION |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | INTERDIGITATED CHANNELS |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Shyam Prasad, K.B. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Maharudrayya, S. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Jayanti, S. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1I940xz0NjbvCm9ebRnZxXpgNbJh5Bfhv/view?usp=drivesdk">https://drive.google.com/file/d/1I940xz0NjbvCm9ebRnZxXpgNbJh5Bfhv/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-11721 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
