Model based PEM fuel cell state-of-health monitoring via ac impedance measurements (Record no. 48055)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02045nam a2200265Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625153930.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-13858 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Model based PEM fuel cell state-of-health monitoring via ac impedance measurements |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Journal of Power Sources, 159(2), p.905-913, 2006 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | The present paper deals with monitoring of flooding and drying out of a proton exchange membrane (PEM)fuel cell using a model-based approach coupled with ac impedance measurements. A study of the impedance response of a 150 cm2 six-cell air/H2 PEM fuel cell as a function of inlet gas relative humidity was carried out. Parameters of a Randles-like equivalent circuit were then fitted to the data. In order to improve the quality of the fit, the classical Randles cell was extended by changing the standard plane capacitor into a constant phase element (CPE). It was found that monitoring the evolution of the three resistances of this modified Randles model was an efficient and robust way of monitoring the state-of-health (SOH)of the fuel cell with respect to the water content of the membrane electrode assembly. Moreover, the non-integer power of the CPE was found to be statistically constant over a wide range of operating conditions, thus comforting the assumption that it has a physical meaning. Qualitative interpretation of the ariation of the parameters as a function of the SOH is proposed in both flooded and dry conditions. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PEM FUEL CELL |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | WATER MANAGEMENT |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | MODEL-BASED FAULT DETECTION AND ISOLATION |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Fouquet, N. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Doulet, C. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Nouillant, C. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Dauphin-Tanguy |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ould-Bouamamab, B. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1rSCK1cRDKRaScCyWLy9lG-tZjVakimD9/view?usp=drivesdk">https://drive.google.com/file/d/1rSCK1cRDKRaScCyWLy9lG-tZjVakimD9/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-13858 | 25.06.2025 | 25.06.2025 | Documentos solicitados |