Thermal conductivity of polyurethane foams from room temperature to 20 K (Record no. 48163)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01692nam a2200241Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625153932.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-13967 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Thermal conductivity of polyurethane foams from room temperature to 20 K |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Cryogenics, 37(6), p.305-312, 1997 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | The thermal conductivity of the polyurethane (PU)foam in the temperature range between 300 and 20 K is investigated theoretically and experimentally for the development of liquid hydrogen storage tanks. An experimental set-up based on the JIS standard A1412 is built to measure the thermal conductivity of the foams under various temperature and pressure conditions. An analytical model, including the contributions from radiative heat transfer, is used to predict the thermal conductivity of the PU foams. The model is found to be able to accurately predict the thermal conductivity of the PU foams under normal and reduced pressures. The thermal conductivity of the PU foam can be reduced by as much as 70(percent)by evacuating the gases in the foam cells. Radiative heat transfer is found to account for about IO-20(percent)at room temperature. The thermal conductivity data below 90 K are available for the first time. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | THERMAL CONDUCTIVITY |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | LIQUID HYDROGEN |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | POLYURETHANE FOAM |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | INSULATION |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Tseng, C-J. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Yamaguchi, M. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ohmori, T. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1BwWcebCf6CBCCkN-L4YyoOEVdKYHYPZL/view?usp=drivesdk">https://drive.google.com/file/d/1BwWcebCf6CBCCkN-L4YyoOEVdKYHYPZL/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-13967 | 25.06.2025 | 25.06.2025 | Documentos solicitados |