AC impedance diagnosis of a 500W PEM fuel cell stack Part II: Individual cell impedance (Record no. 48204)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01897nam a2200265Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625153933.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-14009 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | AC impedance diagnosis of a 500W PEM fuel cell stack Part II: Individual cell impedance |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Journal of Power Sources, 161(2), p.929-937, 2006 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | AC impedance or electrochemical impedance spectroscopy (EIS)has been demonstrated to be a powerful technique for characterizing and evaluating fuel cells. In this work, as an extension of our previous study on the stack impedance of a 500W PEM fuel cell, we report the AC impedance studies on individual cells of the same fuel cell stack. The EIS of the stack with an active area of 280 cm2 was measured at currents from 10 to 210A in steps of 20A using the combination of a FuelCon test station, a TDI loadbank and a Solartron 1260 Frequency Response Analyzer. Measurement of the individual cell EIS was carried out with the help of a rotary switch unit made in our lab. Two methods (floating mode and grounded mode)were utilized for measuring the impedance spectroscopy of the individual cells. The results show that both methods are applicable to individual cells. The results also indicate a good agreement between the total Ohmic loss in the stack and the combined Ohmic losses of the individual cells. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | AC IMPEDANCE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY (EIS) |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PROTON EXCHANGE MEMBRANE FUEL CELL (PEMFC) |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | STACK |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | INDIVIDUAL CELL |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Yuan, X. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Sun, J.C. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Wang, H. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Zhang, J. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1kLOzIP2n6M1fmD5wVUPi1_b8m99p9QAe/view?usp=drivesdk">https://drive.google.com/file/d/1kLOzIP2n6M1fmD5wVUPi1_b8m99p9QAe/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-14009 | 25.06.2025 | 25.06.2025 | Documentos solicitados |