245 10 - TITLE STATEMENT
Title Evaluation of a transient test procedure for solar flat-plate collectors
490 0# - SERIES STATEMENT
Volume/sequential designation Energy, 24, p.979-995, 1999
520 3# - SUMMARY, ETC.
Summary, etc. A dynamic method for testing solar flat-plate collectors under unsteady weather conditions has been validated through detailed experiments and compared with two established standards: the ASHRAE 93- 86 standard for steady state testing and the British standard BS 6757 for transient testing. The new method is based on a lumped capacity model derived from a general energy balance of the collector under actual conditions. The characteristic parameters are estimated using the standard methods for unconditional nonlinear optimisation. Extensive experiments have been carried out under a wide range of operating and environmental conditions. Four different collectors commercially available in the market have been tested at the same location and using the same experimental rig. The results on the basis of the new method are very close to those obtained from the ASHRAE standard. The average values of FR(ta)e and FRUL by the new method are within ±3 percent of the steady state values. The results of the BS 6757 method are within ±2 percent for FR(ta)e but those of FRUL are about 12 percent lower than the ASHRAE values. On average, the difference between the theoretical predictions for the outlet temperature by the new method and the corresponding experimental measurements are about ±0.3°C, while the predictions by the British standard under the same conditions are about 2°C lower than measured values. The percentage deviations of predictions for the temperature rise based on the two methods, averaged over a day, are about ±8 percent and ±36 percent respectively. The new dynamic method requires less time for experimentation, one day's test is enough to give accurate estimation of the collector parameters. The method does not impose any restriction on the variation of weather or operating parameters and, therefore, has a quite general applicability.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Amer, E.H.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Nayak, J.K.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/19waJZ9K_9ppcZx0BGRry1DFfsfaKs0a7/view?usp=drivesdk">https://drive.google.com/file/d/19waJZ9K_9ppcZx0BGRry1DFfsfaKs0a7/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-14052 25.06.2025 25.06.2025 Documentos solicitados