Transient test methods for flat-plate collectors: review and experimental evaluation (Record no. 48248)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02371nam a2200193Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625153934.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-14053 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Transient test methods for flat-plate collectors: review and experimental evaluation |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Solar Energy, 60, p.229-243, 1997 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Abstract This communication presents a review of the literature on the test methods of flat-plate solar collectors under varying environmental conditions. The methods are classified into different groups based on their common features. The methods are examined critically from the point of view of their: (a)experimental procedures, (b)echniques of parameter identification and (c)output results. Four test procedures have been evaluated experimentally in detail. The results from different tests are compared with each other and with the steady state values based on the ASHRAE 93-86 standard. The review reveals that test procedures based on multi-node models may not be implemented accurately in experimentation. They require impractical measurements or lead to complicated equations for estimation of parameters. A few one-node models include inconvenient test runs or confusing data reduction techniques. The results of the experimental investigation indicate that Saunier's method yields arameters close to those obtained on the basis of the ASHRAE standard. However, the results are greatly affected by measurement errors and propagation of error in various test stages. Exell's method eliminates the inconvenient tests of Saunier's method, but includes a long chain of experiments and does not provide a good estimate of collector characteristics. Rogers' method yields a good estimate of optical efficiency, but underpredicts the heat loss term; it also involves a large amount of computation. The filter method leads to a good estimate of the heat loss term, but it overpredicts the optical efficiency. In addition, precise control of the flow rate and inlet temperature is essential in the last two methods. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Amer, E. H. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Nayak, J. K. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Sharma, G. K. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1h_dYeGzQcKC3eGEVE3kUFN1Iako0sklN/view?usp=drivesdk">https://drive.google.com/file/d/1h_dYeGzQcKC3eGEVE3kUFN1Iako0sklN/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-14053 | 25.06.2025 | 25.06.2025 | Documentos solicitados |