Thermal advantages for solar heating systems with a glass cover with antireflection surfaces (Record no. 48489)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02196nam a2200181Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625153938.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-14295 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Thermal advantages for solar heating systems with a glass cover with antireflection surfaces |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Solar Energy, 74, p.513-523, 2003 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Investigations elucidate how a glass cover with antireflection surfaces can improve the efficiency of a solar collector and the thermal performance of solar heating systems. The transmittances for two glass covers for a flat-plate solar collector were measured for different incidence angles. The two glasses are identical, except for the fact that one of them is equipped with antireflection surfaces by the company SunArc A/ S. The transmittance was increased by 5-9(percent)-points due to the antireflection surfaces. The increase depends on the incidence angle. The efficiency at incidence angles of 08 and the incidence angle modifier were measured for a flat-plate solar collector with the two cover plates. The collector efficiency was increased by 4-6(percent)points due to the antireflection surfaces, depending on the incidence angle. The thermal advantage with using a glass cover with antireflection surfaces was determined for different solar heating systems. Three systems were investigated: solar domestic hot water systems, solar heating systems for combined space heating demand and domestic hot water supply, and large solar heating plants. The yearly thermal performance of the systems was calculated by detailed simulation models with collectors with a normal glass cover and with a glass cover with antireflection surfaces. The calculations were carried out for different solar fractions and temperature levels of the solar heating systems. These parameters influence greatly the thermal performance associated with the antireflection surfaces. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Furbo, S. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Jivan Shah, L. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1CQQR8OS1DU86kZmZGdEqqVXjMiXVFckl/view?usp=drivesdk">https://drive.google.com/file/d/1CQQR8OS1DU86kZmZGdEqqVXjMiXVFckl/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-14295 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
