Parameter effects on design and performance of flat plate solar collectors (Record no. 49423)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01347nam a2200169Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625153956.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-15242 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Parameter effects on design and performance of flat plate solar collectors |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Solar Energy, 34(6), p.497-504, 1985 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Under steady-state and transient state conditions, efficiency and warming-up time of flat plate water collectors are calculated. The effects of the variation of a great many parameters are presented. Proper consideration of these effects is important when meteorological conditions are unfavorable. Comparison of collector performance in summer and winter shows the importance of collector inclination, and the effect of pipe spacing. A rule of thumb is given for the approximate transformation of diurnal irradiance curves into effective constant irradiance values. For the conditions considered here an effective irradiance of about 400 W/m 2 in June yields an efficiency of 57 per cent and an effective irradiance of 300 W/m 2 in December gives 46.5 per cent. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Hahne, E. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1DMSHehjjt14vis8hwsqiTieG0te5bOS2/view?usp=drivesdk">https://drive.google.com/file/d/1DMSHehjjt14vis8hwsqiTieG0te5bOS2/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-15242 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
