Evaluation of Transient Electromagnetic Soundings for Deep Detection of Conductive Fluids (Record no. 50707)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02142nam a2200217Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625160153.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-16537 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Evaluation of Transient Electromagnetic Soundings for Deep Detection of Conductive Fluids |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Groundwater, 24(3), p.351-356, 1986 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Transient electromagnetic sounding methods (TEM)have several advantages over DC resistivity soundings. The principal advantage is that sounding depths several times the receiver-transmitter spacing can be achieved, resulting in less cumbersome field work and more flexible sounding site selection. The TEM method was tested using a commercially available instrument (Geonics EM-37)in the Gulf Springs region of west-central Florida to locate the saltwater interface in the Floridan Aquifer. The Floridan is a thick (200 m), unconfined, karstic, carbonate aquifer within the study area. High annual rainfall and internal drainage create a deep and dynamic interface. Eighty transient soundings were completed in 18 field days. Seventy-one soundings used a square 80 m × 80 m transmitter loop, and the other nine used a 160 m × 160 m coil. The interface was easily detected from a minimum depth of 60 m to its maximum depth of about 140 meters. Also, a high-resistivity, low-porosity zone was detected at depths ranging from 180-250 meters. The TEM data compare well with available chloride concentration data. The TEM interface corresponds to chloride values in excess of 200-400 mg/1. The sounding curves obtained suggest that with presently available instruments the TEM method is not well-suited for shallow soundings (less than 40-50 meters). Copyright © 1986, Wiley Blackwell. All rights reserved |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | AQUIFERS - FLORIDA |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | DATA PROCESSING - DATA ACQUISITION |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | HYDROLOGY |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Stewart, M. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Gay, M.C. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1h9iwdaRAT9V2QEulUjMQuKRM1gOokfKz/view?usp=drivesdk">https://drive.google.com/file/d/1h9iwdaRAT9V2QEulUjMQuKRM1gOokfKz/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-16537 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
