Design and analysis of a burst strength device for testing vascular grafts (Record no. 51978)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02076nam a2200229Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625160218.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-17817 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Design and analysis of a burst strength device for testing vascular grafts |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Review of Scientific Instruments, 90(1), p.014301, 2019 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | The design and analysis of a device to measure the burst strength (strength under a state of pure radial internal pressure)and compliance of vascular grafts and flexible pressurized tubes is presented. The device comprises three main sections, viz., a clean air-dry pressure controller, a test specimen holder, and automated software for control and data collection. Air pressure is controlled by means of a valve and a dedicated mechanism allowing reaching up to 120 psi in increments of 1 psi, and recording pressure changes with 0.04 psi resolution. The circumferential strain is determined by measuring the radial displacement of the vascular graft using an optical arrangement capable of determining a maximum radial displacement of 10 mm with 0.02 mm resolution. The instrument provides a low uncertainty in compliance (±0.32 per cent/100 mm Hg?1)and burst strength measurements. Due to its simplicity, the device can easily be reproduced in other laboratories contributing to a dedicated instrument with high resolution at low cost. The reliability of the apparatus is further confirmed by conducting finite element analysis, elasticity solutions for pressurized cylinders, and testing of small diameter vascular grafts made of a commercial aliphatic polyurethane tested under radial internal pressure. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | VASCULAR |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Pérez-Aranda, C. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Gamboa, F. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Castillo-Cruz, O. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Cauich-Rodríguez, J. V |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Avilés, F. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1eagdINExBPwAKrxBNm5odgwkAEm2uQjn/view?usp=drivesdk">https://drive.google.com/file/d/1eagdINExBPwAKrxBNm5odgwkAEm2uQjn/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-17817 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
