Design and analysis of a burst strength device for testing vascular grafts (Record no. 51978)

MARC details
000 -LEADER
fixed length control field 02076nam a2200229Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250625160218.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-17817
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title Design and analysis of a burst strength device for testing vascular grafts
490 0# - SERIES STATEMENT
Volume/sequential designation Review of Scientific Instruments, 90(1), p.014301, 2019
520 3# - SUMMARY, ETC.
Summary, etc. The design and analysis of a device to measure the burst strength (strength under a state of pure radial internal pressure)and compliance of vascular grafts and flexible pressurized tubes is presented. The device comprises three main sections, viz., a clean air-dry pressure controller, a test specimen holder, and automated software for control and data collection. Air pressure is controlled by means of a valve and a dedicated mechanism allowing reaching up to 120 psi in increments of 1 psi, and recording pressure changes with 0.04 psi resolution. The circumferential strain is determined by measuring the radial displacement of the vascular graft using an optical arrangement capable of determining a maximum radial displacement of 10 mm with 0.02 mm resolution. The instrument provides a low uncertainty in compliance (±0.32 per cent/100 mm Hg?1)and burst strength measurements. Due to its simplicity, the device can easily be reproduced in other laboratories contributing to a dedicated instrument with high resolution at low cost. The reliability of the apparatus is further confirmed by conducting finite element analysis, elasticity solutions for pressurized cylinders, and testing of small diameter vascular grafts made of a commercial aliphatic polyurethane tested under radial internal pressure.
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element VASCULAR
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Pérez-Aranda, C.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Gamboa, F.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Castillo-Cruz, O.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Cauich-Rodríguez, J. V
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Avilés, F.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1eagdINExBPwAKrxBNm5odgwkAEm2uQjn/view?usp=drivesdk">https://drive.google.com/file/d/1eagdINExBPwAKrxBNm5odgwkAEm2uQjn/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-17817 25.06.2025 25.06.2025 Documentos solicitados