Experimental study of carbon dioxide as working fluid in a closed-loop compressed gas energy storage system (Record no. 52377)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02242nam a2200253Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625160225.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-18224 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Experimental study of carbon dioxide as working fluid in a closed-loop compressed gas energy storage system |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Renewable Energy, 134, p.603-611, 2019 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | This paper investigates the utilization of carbon dioxide gas available in mass pressurized storage caverns as a working fluid for a modular low pressure compressed gas energy storage (CGES)system. The system is made up of three 7?L cylinders that discharge into an air turbine to convert the system potential energy into kinetic and eventually into electricity through an onboard generator. The operating pressures are kept low (around 3?bar)in order to maintain the adiabatic operational assumption and not necessitate the usage of heat exchangers. The gas is then rerouted back into the storage cavern after expansion. The reported energy conversion efficiency is 46.2 percent for the three active cylinders operating in tandem and 76.4 percent for them operating in unison. The main advantage of the proposed system is its flexibility to function under high power density for the latter or high energy density requirements for the former arrangement, respectively. This level of discharge control allows the system to serve in ranges that previously required independent storage systems addressing narrow power/energy density needs. This charge/discharge cycle takes advantage of the availability of the stored and pressurized carbon dioxide, which is denser than air and hence produced higher power output and required 65 percent less space than its air-operated counterpart. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | CARBON DIOXIDE STORAGE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | MODULAR COMPRESSED AIR STORAGE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | ENERGY STORAGE SYSTEMS |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Alami, A. H. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Hawili, A. A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Hassan, R. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Al-Hemyari, M. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Aokal, K. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1Qj9zTEaKBLPaFAfBAEyY5UEU3o3nIq3O/view?usp=drivesdk">https://drive.google.com/file/d/1Qj9zTEaKBLPaFAfBAEyY5UEU3o3nIq3O/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-18224 | 25.06.2025 | 25.06.2025 | Documentos solicitados |