Cell voltage static-dynamic modeling of a PEM electrolyzer based on adaptive parameters: Development and experimental validation. (Record no. 52748)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02151nam a2200277Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625162415.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-18600 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Cell voltage static-dynamic modeling of a PEM electrolyzer based on adaptive parameters: Development and experimental validation. |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Renewable Energy, 163, p.1508-1522, 2021 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | This article aims to propose and experimentally validate a static-dynamic electrical model of a proton exchange membrane (PEM)electrolyzer. The originality of this work concerns the cell voltage modeling according to static and dynamic operations. Indeed, the cells of the PEM electrolyzer may be subjected to degradations due to the operating conditions and current ripple generated by power electronics. Hence, cell voltage response and efficiency may be affected. For this reason, it is crucial to model each cell voltage to investigate the degradation and wear effects mainly caused by the dynamic operating conditions met when coupling with renewable energy sources and current ripple from power electronics. To develop an accurate model, static and dynamic operations are investigated on a commercial-400 W PEM electrolyzer stack. To enhance the accuracy of the model in replicating the real behavior of the electrolyzer, the parameters of the model are adapted according to the input current. The comparison between the experimental data and the developed model has enabled confirming the effectiveness of the model to reproduce the cell voltage static and dynamic behavior according to the input current |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PEM ELECTROLYZER |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | MODELING |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | CURRENT RIPPLE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | STATIC-DYNAMIC |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | RENEWABLE ENERGY SOURCES |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | ADAPTIVE PARAMETERS |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Hernández-Gómez, Á. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ramirez, V. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Guilbert, D. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Saldivar, B. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/12AzTAh-hd3eeXJ50Iuk6MFSxTRhl_NDy/view?usp=drivesdk">https://drive.google.com/file/d/12AzTAh-hd3eeXJ50Iuk6MFSxTRhl_NDy/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-18600 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
