Assessment of photovoltaic power generation using fin augmented passive cooling technique for different climates (Record no. 53112)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02369nam a2200301Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625162422.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-18970 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Assessment of photovoltaic power generation using fin augmented passive cooling technique for different climates |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Sustainable Energy Technologies and Assessments, 52, 102095, 2022 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | This research work entails a methodical study tackling one deterrent causing lower conversion efficiency for photovoltaic system, i.e., module temperature. Based on literature, a passive cooling system comprising of fins has been designed and an overall assessment has been conducted for fins integrated photovoltaic modules to enhance overall performance. A collective experimental and simulation study has been conducted to evaluate the effectiveness of passive cooling system in mitigating high module temperatures. The results of the experiment conducted during 3 months (from October-March), presented an average overall efficiency increment of 5.47 percent with curtailment of 40 percent in temperature coefficient for variable outdoor conditions. The simulations conducted further presented good results, highlighting the effectiveness of the proposed method of module cooling for hot climatic regions with an enhancement up to 6 percent . In contrast, lower gain (up to 2 percent ) was realised for colder regions. Further analysis revealed that the difference in array temperature for hotter climate is over 10 ?C between original and modified system, while no considerable variation was found for colder climates. Cooling the module proved to be an effective method of enhancing performance, while future cost-based studies may assist in establishing the feasibility of cooling strategies for variable climates. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PASSIVE COOLING |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | TEMPERATURE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | FINS |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PVSYST |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PERFORMANCE RATIO |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | LOSSES |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Raina, G. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Sinha, S. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Saini, G. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Sharma, S. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Malik, P. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Thakur, N. S. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/1RgEVzv-NxrSrCc4XX52wTh7CmW8w7-1t/view?usp=drivesdk">https://drive.google.com/file/d/1RgEVzv-NxrSrCc4XX52wTh7CmW8w7-1t/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-18970 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
