Experimental and numerical modelling of hygrothermal transfer: Application on building energy performance (Record no. 53326)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02117nam a2200277Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625162426.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-19188 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Experimental and numerical modelling of hygrothermal transfer: Application on building energy performance |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Energy and Buildings, 254, p.111633, 2022 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | This work deals with the hygrothermal behavior of building envelope wall composed of an eco-concrete made of glass powder. The material was chosen in order to satisfy the RE2020 requirements regarding the carbon footprint reduction of building materials. The wall is tested and subjected to wetting/drying cycles by T/RH variations with/without solar radiations and rainfall. The last two climatic conditions are real and rarely taken into account in the study of hygrothermal behavior. Therefore, an experimental set-up was designed and a numerical model was proposed. The numerical and experimental results were compared for the both tests. The results obtained highlighted the ability of the numerical model to reproduce the hygrothermal behavior of the wall. For Test 1, the RMSE value is about 0.24 °C, 4.78 percent and 2.28 W.m?2 for T, RH and thermal flux, respectively. Whereas, it is about 0.23 °C, 3.47 percent and 7.79 W.m?2 for Test 2. The impact of rainfall is 3.33 time more than the test without rain for a material with porosity about 14.18 percent . As for drying, the solar radiations has an important intensity of about 820 W.m?2 and induces a significant heat flux at the external border. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | HYGROTHERMAL TRANSFER |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | SOLAR RADIATION |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | RAINFALL |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | EXPERIMENTAL BENCH |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | ECO-CONCRETE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | CHEMICAL ANALYSIS |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Boukhelf, F. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Trabelsi, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Belarbi, R. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Bouiadjra, M. B. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/file/d/156spUBLJAaFr3fiWxGKjWE4ErVP6O1sT/view?usp=drivesdk">https://drive.google.com/file/d/156spUBLJAaFr3fiWxGKjWE4ErVP6O1sT/view?usp=drivesdk</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-19188 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
