In-situ monitoring of glass fiber/epoxy composites by the embedded multi-walled carbon nanotube coated glass fiber sensor: From fabrication to application (Record no. 54357)

MARC details
000 -LEADER
fixed length control field 02139nam a2200289Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250625162445.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-20257
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title In-situ monitoring of glass fiber/epoxy composites by the embedded multi-walled carbon nanotube coated glass fiber sensor: From fabrication to application
490 0# - SERIES STATEMENT
Volume/sequential designation Polymer Composites, 43(7), p.4210-4222, 2022
520 3# - SUMMARY, ETC.
Summary, etc. Monitoring the curing defects as well as damages that occur in the fabrication and application process is important for ensuring the safety of composite structures. In this paper, a highly sensitive 1-D line sensor is designed to achieve self-sensing and diagnosing functionalities in both the fabrication and application of glass fiber reinforced epoxy (GF/epoxy)composites. The sensor consists of multi-walled carbon nanotube coated glass fiber (MWCNT@GF), which is sensing the damage by the principle of resistance change. Due to the vacuum-assisted resin infusion process, the MWCNT@GF sensor is embedded into GF/epoxy composite laminates, and hence, it can monitor the resin frontal flow, curing, and especially the flow defects. In the subsequent application, the tensile performance of a GF/epoxy composite joint is evaluated by not only the force-displacement curve but also the displacement-dependent resistance change of the sensor. Tensile damage modes are distinguished, which is for the first time to be reported. The MWCNT@GF sensor is mechanically stable and highly sensitive; hence, it can be used to follow the composite performance from fabrication until the end of life.
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element COMPOSITE JOINT
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element CURING MONITORING
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element IN-SITU MONITORING
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element MWCNT@GF SENSOR
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Wan, Y.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Hu, W.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Yang, L.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Wang, Z.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Tan, J.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Liu, Y.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Yang, B.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1wPf65bGnnTEXsDihRX_ZgdEto7P7MY3_/view?usp=drivesdk">https://drive.google.com/file/d/1wPf65bGnnTEXsDihRX_ZgdEto7P7MY3_/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-20257 25.06.2025 25.06.2025 Documentos solicitados