Standardization of micro-FTIR methods and applicability for the detection and identification of microplastics in environmental matrices (Record no. 54614)

MARC details
000 -LEADER
fixed length control field 03094nam a2200289Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250625162450.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-20525
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title Standardization of micro-FTIR methods and applicability for the detection and identification of microplastics in environmental matrices
490 0# - SERIES STATEMENT
Volume/sequential designation Science of the Total Environment, 888, p.164157, 2023
520 3# - SUMMARY, ETC.
Summary, etc. The ubiquity of microplastics (MPs)in the various environment is of increasing concern. Although micro Fourier Transform Infrared Spectroscopy (?-FTIR)represents an ideal method for the detection of MPs, this technique lacks a standardized mode to be followed for MPs in diverse environmental matrices. The study focused on the optimization, application, and validation of ?-FTIR techniques for the identification of smaller-sized MPs (20 ?m-1 mm). In order to assess the validity of the various detection modes in ?-FTIR (reflection and transmission), a confirmatory test with known standard polymers, viz., polyethylene (PE), polypropylene (PP), polystyrene (PS), polyamide (PA), and polyvinyl chloride (PVC)were executed. Subsequently, for the validation and accuracy of the method, the polymer spectra of standard polymers acquired in ?-FTIR (smaller-sized)were compared with spectra of larger-sized particles (same standards)in FTIR-ATR (Attenuated Total Reflectance). The spectra were comparable and highlighted the similar pattern of the polymeric composition. The spectral quality and matching score (>60 percent)with the reference library was taken into account to accentuate the authenticity of the different methods. This study highlighted the reflection mode (particularly diffuse reflection)as more effective for the quantification of smaller-sized MPs in complex environmental samples. The same method was successfully applied to a representative environmental sample (sand), supplied by the EURO-QCHARM for inter-laboratory study. Two polymers (PE and PET)were correctly identified out of three spiked polymers (PE, PET, and PS)in the given sample. Similarly, in terms of matching algorithms, the results for diffuse reflection (PE-71.7 percent and PET-89.1 percent)were found satisfactory as compared to micro-ATR (PE-67 percent and PET-63.2 percent)reflection mode. Overall, this study illustrates an extensive perspective of different ?-FTIR techniques, recommending the most reliable, easy, and non-destructive method to unambiguously characterize diverse types of polymers of smaller MPs in complex environmental matrices.
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element MICROPLASTICS
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element MICRO-FTIR
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element SPECTROSCOPY
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element DETECTION MODES
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element POLYMER IDENTIFICATION
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Rathore, C.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Saha, M.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Gupta, P.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Kumar, M.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Naik, A.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name De Boer, J.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1o898dPf9Mv4ZB_VTotQbrOARVHARqJ4-/view?usp=drivesdk">https://drive.google.com/file/d/1o898dPf9Mv4ZB_VTotQbrOARVHARqJ4-/view?usp=drivesdk</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 25.06.2025   B-20525 25.06.2025 25.06.2025 Documentos solicitados