Temperature and pH sensors based on graphenic materials (Record no. 55137)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02014nam a2200289Ia 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | MX-MdCICY |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250625162500.0 |
| 040 ## - CATALOGING SOURCE | |
| Transcribing agency | CICY |
| 090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) | |
| Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) | B-21059 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250602s9999 xx |||||s2 |||| ||und|d |
| 245 10 - TITLE STATEMENT | |
| Title | Temperature and pH sensors based on graphenic materials |
| 490 0# - SERIES STATEMENT | |
| Volume/sequential designation | Biosensors and Bioelectronics, 91, p.870-877, 2017 |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Point-of-care applications and patients' real-time monitoring outside a clinical setting would require disposable and durable sensors to provide better therapies and quality of life for patients. This paper describes the fabrication and performances of a temperature and a pH sensor on a biocompatible and wearable board for healthcare applications. The temperature sensor was based on a reduced graphene oxide (rGO)layer that changed its electrical resistivity with the temperature. When tested in a human serum sample between 25 and 43 °C, the sensor had a sensitivity of 110±10 ?/°C and an error of 0.4±0.1 °C compared with the reference value set in a thermostatic bath. The pH sensor, based on a graphene oxide (GO)sensitive layer, had a sensitivity of 40±4 mV/pH in the pH range between 4 and 10. Five sensor prototypes were tested in a human serum sample over one week and the maximum deviation of the average response from reference values obtained by a glass electrode was 0.2 pH units. For biological applications, the temperature and pH sensors were successfully tested for in vitro cytotoxicity with human fibroblast cells (MRC-5)over 24 h. |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | PH |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | TEMPERATURE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | GRAPHENE |
| 650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | FLEXIBLE SENSOR |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Salvo, P. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Calisi, N. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Melai, B. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Cortigiani, B. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mannini, M. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Caneschi, A. |
| 700 12 - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Di Francesco, F. |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://drive.google.com/open?id=1iLkF2FZ_bNgSa24_It6R-EexhVlZ0nVr&usp=drive_copy">https://drive.google.com/open?id=1iLkF2FZ_bNgSa24_It6R-EexhVlZ0nVr&usp=drive_copy</a> |
| Public note | Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Clasificación local |
| Koha item type | Documentos solicitados |
| Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection | Home library | Current library | Shelving location | Date acquired | Total checkouts | Full call number | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Clasificación local | Ref1 | CICY | CICY | Documento préstamo interbibliotecario | 25.06.2025 | B-21059 | 25.06.2025 | 25.06.2025 | Documentos solicitados |
