PLCL-TPU bi-layered artificial blood vessel with compliance matching to host vessel (Record no. 55538)

MARC details
000 -LEADER
fixed length control field 02647nam a2200289Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250626080925.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-12880
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250602s9999 xx |||||s2 |||| ||und|d
245 10 - TITLE STATEMENT
Title PLCL-TPU bi-layered artificial blood vessel with compliance matching to host vessel
490 0# - SERIES STATEMENT
Series statement Journal of Biomaterials Applications, 38(2), p.194-202, 2023
500 ## - GENERAL NOTE
General note Artículo
520 3# - SUMMARY, ETC.
Summary, etc. Compliance mismatch between the artificial blood vessel and the host vessel leads to abnormal hemodynamics and is a major mechanical trigger of intimal hyperplasia. Efforts have been made to achieve higher compliance of artificial blood vessels. However, the preparation of artificial blood vessels with compliance matching to host vessels has not been realized. A bi-layered artificial blood vessel was successfully prepared by dip-coating and electrospinning composite method using poly(L-Lactide-co-caprolactone) (PLCL) and thermoplastic poly(ether urethane) (TPU). In the case of a certain wall thickness (200 μm), thickness ratios of the PLCL inner layer (dip-coating method) and TPU outer layer (electrospinning method) were controlled at 0:1, 1:9, 3:7, 5:5, 7:3, and 1:0 respectively and the compliance, radial tensile properties, burst pressure, and suture retention strength were investigated. Results showed compliance value of the artificial blood vessel decreased with the increase of the thickness ratio, which suggested the compliance of the bi-layered artificial blood vessel can be regulated by adjusting the ratio of the inner and outer layer thicknesses. In the six different artificial blood vessels, the one with thickness ratio of 1:9 not only had high compliance (8.768 ± 0.393 percent/100 mmHg) but also can guarantee the other mechanical properties, such as the radial breaking strength (6.333 ± 0.689 N/mm), burst pressure (534.473 ± 20.899 mmHg), and suture retention strength (300.773 ± 9.351 cN). The proposed artificial blood vessel preparation method is expected to achieve compliance matching with the host vessel. It is beneficial for eliminating abnormal he[1]modynamics and reducing intimal hyperplasia
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element ARTIFICIAL BLOOD VESSEL
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element COMPLIANCE
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element DIP-COATING
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element ELECTROSPINNING
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element HEMODYNAMICS
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Guan, L.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Zhao, H.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Wang, K.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Zhang, K. Q.
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name Meng, K.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1zVPMtkB94nb7ISWHhLKn-EQLXthg7Fvi/view?usp=drive_link">https://drive.google.com/file/d/1zVPMtkB94nb7ISWHhLKn-EQLXthg7Fvi/view?usp=drive_link</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 26.06.2025   B-12880 26.06.2025 26.06.2025 Documentos solicitados