Cross-linked polysulfone membranes with controllable cross-linkers for anion-exchange membrane water electrolysis (Record no. 61919)

MARC details
000 -LEADER
fixed length control field 02111nam a2200241Ia 4500
003 - CONTROL NUMBER IDENTIFIER
control field MX-MdCICY
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20251009160707.0
040 ## - CATALOGING SOURCE
Transcribing agency CICY
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) B-21829
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 251009s9999 xx 000 0 und d
245 10 - TITLE STATEMENT
Title Cross-linked polysulfone membranes with controllable cross-linkers for anion-exchange membrane water electrolysis
490 0# - SERIES STATEMENT
Series statement European Polymer Journal, 221, p.113543, 2024
500 ## - GENERAL NOTE
General note Artículo
520 3# - SUMMARY, ETC.
Summary, etc. We report polysulfone-based anion-exchange membranes cross-linked using three distinct cross-linkers (i.e., 4,4′- trimethylenebis(1-methyl-piperidine) (BMP), N,N,N′,N′-tetramethyl-1,6-diaminohexane (TMHDA), and 1,4-dia zabicyclo[2.2.2]octane (DABCO)), designed for water electrolysis application. The cross-linked chloromethy lated polysulfone membranes exhibit quaternization functionality, which can facilitate hydroxide-ion transport. Additionally, the cross-linked polysulfone membranes exhibit high thermal and mechanical stability. Among the cross-linked polysulfone membranes, the BMP-induced cross-linked polysulfone membrane displays an ionexchange capacity of 1.58 mmol/g and an ion conductivity of 53.7 mS/cm at 80 ◦C, along with a water up take of 50 percent and a swelling ratio of 23 percent, demonstrating good electrochemical properties and high dimensional stability. Moreover, the BMP-induced cross-linked polysulfone membrane exhibits a higher anion-exchange membrane water electrolysis performance and lower impedance than the other cross-linker-induced crosslinked polysulfone membranes. More importantly, it exhibits better water electrolysis cell performance than commercial FAA-3-50 membranes.
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element ANION-EXCHANGE MEMBRANES
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element WATER ELECTROLYZERS
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element POLYSULFONE
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element CROSS-LINKING
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element QUATERNIZATION
700 12 - ADDED ENTRY--PERSONAL NAME
Personal name An, E. J.;Sim, G. H.;Yu, S.;Kim, H. G.;An, S. J.;Lee, C.;Chi, W. S.
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1GpXPeGzrlyPTczOOflx4zvrn1JLzxuTh/view?usp=drive_link">https://drive.google.com/file/d/1GpXPeGzrlyPTczOOflx4zvrn1JLzxuTh/view?usp=drive_link</a>
Public note Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Clasificación local
Koha item type Documentos solicitados
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection Home library Current library Shelving location Date acquired Total checkouts Full call number Date last seen Price effective from Koha item type
  Clasificación local     Ref1 CICY CICY Documento préstamo interbibliotecario 09.10.2025   B-21829 09.10.2025 09.10.2025 Documentos solicitados