Image from Google Jackets

A cost effective non-commercial ECL-solution for Western blot detections yielding strong signals and low background

Tipo de material: TextoTextoSeries ; Journal of Immunological Methods, 318(1-2), p.11-19, 2007Trabajos contenidos:
  • Haan, C
  • Behrmann, I
Tema(s): Recursos en línea: Resumen: We compared several alternative ECL solutions for Western blot detection of endogenous proteins in whole cell lysates using inexpensive, commercially available reagents. Starting from an existing protocol based on p-coumaric acid (pCA)as enhancer, we found that the ECL solution containing 4-iodophenylboronic acid (4IPBA)generated strong specific signals and low background chemiluminescence. We optimised the luminol, 4IPBA and hydrogenperoxide concentrations of this 4IPBA-ECL solution. The optimised 4IPBA-ECL solution (100 mM Tris/HCl pH 8.8, 1.25 mM luminol, 2 mM 4IPBA, 5.3 mM hydrogenperoxide)shows a greatly increased signal intensity compared to the initial pCA-ECL protocol and to some commercially available ECL solutions. In addition, the optimised 4IPBA-ECL solution also generates much lower background chemiluminescence than other noncommercial ECL solutions using p-coumaric acid or 4-iodophenol as enhancers. The 4IPBA-ECL solution was table when stored but had the lowest background when prepared freshly from stock solutions. Thus, we present an optimised protocol for a wellperforming inexpensive ECL solution which is an alternative to expensive commercial ECL solutions and which achieves a better signal and lower background than the commercial solutions tested.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode
Documentos solicitados Documentos solicitados CICY Documento préstamo interbibliotecario Ref1 B-12529 (Browse shelf(Opens below)) Available

We compared several alternative ECL solutions for Western blot detection of endogenous proteins in whole cell lysates using inexpensive, commercially available reagents. Starting from an existing protocol based on p-coumaric acid (pCA)as enhancer, we found that the ECL solution containing 4-iodophenylboronic acid (4IPBA)generated strong specific signals and low background chemiluminescence. We optimised the luminol, 4IPBA and hydrogenperoxide concentrations of this 4IPBA-ECL solution. The optimised 4IPBA-ECL solution (100 mM Tris/HCl pH 8.8, 1.25 mM luminol, 2 mM 4IPBA, 5.3 mM hydrogenperoxide)shows a greatly increased signal intensity compared to the initial pCA-ECL protocol and to some commercially available ECL solutions. In addition, the optimised 4IPBA-ECL solution also generates much lower background chemiluminescence than other noncommercial ECL solutions using p-coumaric acid or 4-iodophenol as enhancers. The 4IPBA-ECL solution was table when stored but had the lowest background when prepared freshly from stock solutions. Thus, we present an optimised protocol for a wellperforming inexpensive ECL solution which is an alternative to expensive commercial ECL solutions and which achieves a better signal and lower background than the commercial solutions tested.

There are no comments on this title.

to post a comment.