| 245 | 1 | 0 | _aAcid dissolution methods for heavy metals determination in pine needles |
| 490 | 0 | _vEnviron. Chem. Lett., 1(3), p.191-195, 2003 | |
| 520 | 3 | _aMicrowave digestion procedures using HNO3, HNO3+H2O2, HNO3+HClO4, HF mixtures and dry ashing with HF were investigated for heavy metals analysis by either inductively coupled plasma-optical emission spectroscopy (ICP-OES)or ICP-mass spectrometry (ICP-MS)in pine needles. The HF digestion procedures gave about 1.5 times higher values than a mixture of HNO3+H2O2 alone. For Ti determination in needles, the HF procedure using dry ashing is thus recommended. The mean concentrations amounted to 900 mg/kg for Fe and 21.8 mg/kg for Ti in needles collected at an area polluted by a stainless steel works. Those concentrations were 10.6 and 4.3 times higher than in needles collected at an area nearby a pulp mill complex (84.5 mg/kg Fe and 5.0 mg/kg Ti). | |
| 650 | 1 | 4 | _aPINE NEEDLES |
| 650 | 1 | 4 | _aDISSOLUTION |
| 650 | 1 | 4 | _aPULP AND PAPER MILLS |
| 650 | 1 | 4 | _aFERROCHROME AND STAINLESS STEEL WORKS |
| 700 | 1 | 2 | _aPoykio, R. |
| 700 | 1 | 2 | _aPeramaki, P. |