000 03254nam a2200289Ia 4500
003 MX-MdCICY
005 20250625162425.0
040 _cCICY
090 _aB-19118
245 1 0 _aIn vitro and in vivo degradation of porous poly(DL-lactic-co-glycolic acid)foams
490 0 _vBioMaterials, 21(18), p.1837-1845, 2000
520 3 _aThis study investigated the in vitro degradation of porous poly(dl-lactic-co-glycolic acid)(PLGA)foams during a 20-week period in pH 7.4 phosphate-buffered saline (PBS)at 37°C and their in vivo degradation following implantation in rat mesentery for up to 8 weeks. Three types of PLGA 85 : 15 and three types of 50 : 50 foams were fabricated using a solvent-casting, particulate-leaching technique. The two types had initial salt weight fraction of 80 and 90 percent , and a salt particle size of 106-150 ?m, while the third type had 90 percent initial weight fraction of salt in the size range 0-53 ?m. The porosities of the resulting foams were 0.82, 0.89, and 0.85 for PLGA 85 : 15, and 0.73, 0.87, and 0.84 for PLGA 50 : 50 foams, respectively. The corresponding median pore diameters were 30, 50, and 17 ?m for PLGA 85 : 15, and 19, 17, and 17 ?m for PLGA 50 : 50. The in vitro and in vivo degradation kinetics of PLGA 85 : 15 foams were independent of pore morphology with insignificant variation in foam weight, thickness, pore distribution, compressive creep behavior, and morphology during degradation. The in vitro foam half-lives based on the weight average molecular weight were 11.1±1.8 (80 percent , 106-150 ?m), 12.0±2.0 (90 percent , 106-150 ?m), and 11.6±1.3 (90 percent , 0-53 ?m)weeks, similar to the corresponding values of 9.4±2.2, 14.3±1.5, and 13.7±3.3 weeks for in vivo degradation. In contrast, all PLGA 50 : 50 foams exhibited significant change in foam weight, water absorption, and pore distribution after 6-8 weeks of incubation with PBS. The in vitro foam half-lives were 3.3±0.3 (80 percent , 106-150 ?m), 3.0±0.3 (90 percent , 106-150 ?m), and 3.2±0.1 (90 percent , 0-53 ?m)weeks, and the corresponding in vivo half-lives were 1.9±0.1, 2.2±0.2, and 2.4±0.2 weeks. The significantly shorter half-lives of PLGA 50 : 50 compared to 85 : 15 foams indicated their faster degradation both in vitro and in vivo. In addition, PLGA 50 : 50 foams exhibited significantly faster degradation in vivo as compared to in vitro conditions due to an autocatalytic effect of the accumulated acidic degradation products in the medium surrounding the implants. These results suggest that the polymer composition and environmental conditions have significant effects on the degradation rate of porous PLGA foams.
650 1 4 _aPOLY(DL-LACTIC-CO-GLYCOLIC ACID)(PLGA)
650 1 4 _aPOROUS FOAMS
650 1 4 _aPOLYMER DEGRADATION
650 1 4 _aTISSUE ENGINEERING
700 1 2 _aLu, L.
700 1 2 _aPeter, S. J.
700 1 2 _aLyman, M. D.
700 1 2 _aLai, H. L.
700 1 2 _aLeite, S. M.
700 1 2 _aTamada, J. A.
700 1 2 _aMikos, A. G
856 4 0 _uhttps://drive.google.com/file/d/1Ja5CzSGzpgNNMQepqC_ycpXsHjH5g6U3/view?usp=drivesdk
_zPara ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx
942 _2Loc
_cREF1
008 250602s9999 xx |||||s2 |||| ||und|d
999 _c53257
_d53257