000 02873nam a2200325Ia 4500
003 MX-MdCICY
005 20250625164354.0
040 _cCICY
090 _aB-21395
245 1 0 _aQuantification and discovery of quality markers from Toddalia asiatica by UHPLC-MS/MS coupled with chemometrics
490 0 _aPhytochemical Analysis. 35(4), 634-646, 2024, DOI: 10.1002/pca.3318
520 3 _aIntroduction: Toddalia asiatica (TA) is a classical traditional Chinese medicine used to treat rheumatoid arthritis and contusions. However, research regarding TA quality control is currently limited. Objective: We aimed to establish a strategy for identifying quality markers that can be used for the evaluation of the quality of TA. Method: A rapid and efficient ultra-high-performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantitative determination of 19 compounds in TA from different regions. Then, the extraction process of TA was successively optimized by single-factor optimization and response surface methodology. Moreover, chemometrics was employed to confirm the correlation between quality and target compounds. Results: Utilizing the UHPLC-MS/MS method, separation of the 19 bioactive compounds was achieved within 14 min. The method was validated in terms of linearity (r2 > 0.9982), precision (0.08%-3.70%), repeatability (0.50%-2.54%), stability (2.26%-5.46%), and recovery (95.8%-113%). The optimal extraction process (extraction solvent, 65% ethanol aqueous solution; solid-liquid ratio, 1:20; extraction time, 25 min) was determined with the total content of 19 bioactive compounds as indicator. Significant disparities were observed in the contents of target compounds across different batches of TA. Besides, all samples could be categorized into two distinct groups, and magnoflorine, (?)-lyoniresinol, nitidine chloride, norbraylin, skimmianine, and decarine were identified as quality markers. Conclusion: In the present study, we developed a strategy to improve the quality control of TA. In consideration of the pharmacodynamic activity and statistical differences, six compounds are proposed as quality markers for TA. © 2024 John Wiley & Sons Ltd.
650 1 4 _aEXTRACTION PROCESS OPTIMIZATION
650 1 4 _aMARKER ANALYSIS
650 1 4 _aQUALITY CONTROL
650 1 4 _aTODDALIA ASIATICA
650 1 4 _aUHPLC-MS/MS
700 1 2 _aWang R.
700 1 2 _aYu C.
700 1 2 _aShang Y.
700 1 2 _aWen J.
700 1 2 _aWei W.
700 1 2 _aDu K.
700 1 2 _aLi J.
700 1 2 _aFang S.
700 1 2 _aChang Y.
856 4 0 _uhttps://drive.google.com/file/d/1y9Pee5Fzh1t_XXgc-MwNsYoYVLqO4Qpb/view?usp=drive_link
_zPara ver el documento ingresa a Google con tu cuenta @cicy.edu.mx
942 _2Loc
_cREF1
008 250602s9999 xx |||||s2 |||| ||und|d
999 _c55455
_d55455