PLCL-TPU bi-layered artificial blood vessel with compliance matching to host vessel

Tipo de material: TextoTextoSeries Journal of Biomaterials Applications, 38(2), p.194-202, 2023Trabajos contenidos:
  • Guan, L
  • Zhao, H
  • Wang, K
  • Zhang, K. Q
  • Meng, K
Tema(s): Recursos en línea: Resumen: Compliance mismatch between the artificial blood vessel and the host vessel leads to abnormal hemodynamics and is a major mechanical trigger of intimal hyperplasia. Efforts have been made to achieve higher compliance of artificial blood vessels. However, the preparation of artificial blood vessels with compliance matching to host vessels has not been realized. A bi-layered artificial blood vessel was successfully prepared by dip-coating and electrospinning composite method using poly(L-Lactide-co-caprolactone) (PLCL) and thermoplastic poly(ether urethane) (TPU). In the case of a certain wall thickness (200 μm), thickness ratios of the PLCL inner layer (dip-coating method) and TPU outer layer (electrospinning method) were controlled at 0:1, 1:9, 3:7, 5:5, 7:3, and 1:0 respectively and the compliance, radial tensile properties, burst pressure, and suture retention strength were investigated. Results showed compliance value of the artificial blood vessel decreased with the increase of the thickness ratio, which suggested the compliance of the bi-layered artificial blood vessel can be regulated by adjusting the ratio of the inner and outer layer thicknesses. In the six different artificial blood vessels, the one with thickness ratio of 1:9 not only had high compliance (8.768 ± 0.393 percent/100 mmHg) but also can guarantee the other mechanical properties, such as the radial breaking strength (6.333 ± 0.689 N/mm), burst pressure (534.473 ± 20.899 mmHg), and suture retention strength (300.773 ± 9.351 cN). The proposed artificial blood vessel preparation method is expected to achieve compliance matching with the host vessel. It is beneficial for eliminating abnormal he[1]modynamics and reducing intimal hyperplasia
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode
Documentos solicitados Documentos solicitados CICY Documento préstamo interbibliotecario Ref1 B-12880 (Browse shelf(Opens below)) Available

Artículo

Compliance mismatch between the artificial blood vessel and the host vessel leads to abnormal hemodynamics and is a major mechanical trigger of intimal hyperplasia. Efforts have been made to achieve higher compliance of artificial blood vessels. However, the preparation of artificial blood vessels with compliance matching to host vessels has not been realized. A bi-layered artificial blood vessel was successfully prepared by dip-coating and electrospinning composite method using poly(L-Lactide-co-caprolactone) (PLCL) and thermoplastic poly(ether urethane) (TPU). In the case of a certain wall thickness (200 μm), thickness ratios of the PLCL inner layer (dip-coating method) and TPU outer layer (electrospinning method) were controlled at 0:1, 1:9, 3:7, 5:5, 7:3, and 1:0 respectively and the compliance, radial tensile properties, burst pressure, and suture retention strength were investigated. Results showed compliance value of the artificial blood vessel decreased with the increase of the thickness ratio, which suggested the compliance of the bi-layered artificial blood vessel can be regulated by adjusting the ratio of the inner and outer layer thicknesses. In the six different artificial blood vessels, the one with thickness ratio of 1:9 not only had high compliance (8.768 ± 0.393 percent/100 mmHg) but also can guarantee the other mechanical properties, such as the radial breaking strength (6.333 ± 0.689 N/mm), burst pressure (534.473 ± 20.899 mmHg), and suture retention strength (300.773 ± 9.351 cN). The proposed artificial blood vessel preparation method is expected to achieve compliance matching with the host vessel. It is beneficial for eliminating abnormal he[1]modynamics and reducing intimal hyperplasia